Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 2.699
1.
J Am Coll Cardiol ; 83(19): 1902-1916, 2024 May 14.
Article En | MEDLINE | ID: mdl-38719370

Postinfarction ventricular free-wall rupture is a rare mechanical complication, accounting for <0.01% to 0.02% of cases. As an often-catastrophic event, death typically ensues within minutes due to sudden massive hemopericardium resulting in cardiac tamponade. Early recognition is pivotal, and may allow for pericardial drainage and open surgical repair as the only emergent life-saving procedure. In cases of contained rupture with pseudo-aneurysm (PSA) formation, hospitalization with subsequent early surgical intervention is warranted. Not uncommonly, PSA may go unrecognized in asymptomatic patients and diagnosed late during subsequent cardiac imaging. In these patients, the unsettling risk of complete rupture demands early surgical repair. Novel developments, in the field of transcatheter-based therapies and multimodality imaging, have enabled percutaneous PSA repair as a feasible alternate strategy for patients at high or prohibitive surgical risk. Contemporary advancements in the diagnosis and treatment of postmyocardial infarction ventricular free-wall rupture and PSA are provided in this review.


Aneurysm, False , Heart Rupture, Post-Infarction , Myocardial Infarction , Humans , Aneurysm, False/etiology , Aneurysm, False/therapy , Myocardial Infarction/complications , Heart Rupture, Post-Infarction/etiology , Heart Rupture, Post-Infarction/diagnosis , Heart Ventricles/diagnostic imaging , Heart Aneurysm/etiology , Heart Aneurysm/surgery
2.
World J Urol ; 42(1): 280, 2024 May 01.
Article En | MEDLINE | ID: mdl-38693433

OBJECTIVE: To perform a comprehensive narrative review that will examine the risk factors and treatment outcomes of arterial pseudoaneurysm following laser flexible ureteroscopy (F-URS). METHODS: A retrospective case series and a review of literature was performed. Clinical records from three patients treated for postoperative arterial pseudoaneurysm from January of 2021 to November 2023 were identified. A comprehensive literature review was also performed. The MEDLINE and Scopus databases were searched. The analysis was made by a narrative synthesis. RESULTS: Three cases of postoperative arterial pseudoaneurysm were included, one from our center, one from Dubai, UAE, and one from Barcelona. The literature review identified six case reports, two after endocorporeal laser lithotripsy with thulium fiber laser (TFL) and four with Ho:YAG laser. All cases, from our series and literature review, presented with macroscopic hematuria and used high-power laser settings. All cases were treated by selective embolization. CONCLUSION: Ho:YAG or TFL lasers are both capable of causing arterial pseudoaneurysms following F-URS if high-power settings are used. Selective artery embolization continues to be the treatment of choice with good outcomes.


Aneurysm, False , Lithotripsy, Laser , Aged , Female , Humans , Male , Middle Aged , Aneurysm, False/etiology , Aneurysm, False/therapy , Lithotripsy, Laser/adverse effects , Lithotripsy, Laser/methods , Postoperative Complications/etiology , Retrospective Studies , Ureteroscopy/adverse effects , Adult
3.
J Med Case Rep ; 18(1): 191, 2024 Apr 19.
Article En | MEDLINE | ID: mdl-38637904

BACKGROUND: Renal artery pseudoaneurysm following partial nephrectomy is a rare entity, the incidence of this entity is more common following penetrating abdominal injuries, percutaneous renal interventions such as percutaneous nephrostomy(PCN) or Percutaneous nephrolithotomy (PCNL). Although rare, renal artery pseudoaneurysm can be life threatening if not managed timely, they usually present within two weeks postoperatively with usual presenting complains being gross haematuria, flank pain and/or anaemia. CASE PRESENTATION: We report case of two female patients 34 and 57 year old respectively of South Asian ethnicity, presenting with renal artery pseudoaneurysm following left sided robot assisted nephron sparing surgery for interpolar masses presenting clinically with total, painless, gross haematuria with clots within fifteen days postoperatively and their successful treatment by digital subtraction angiography and coil embolization. CONCLUSION: Renal artery aneurysm is a rare fatal complication of minimally invasive nephron sparing surgery however considering the preoperative and intraoperative risk factors for its development and prompt suspicion at the outset can be life saving with coil embolization of the bleeding arterial aneurysm.


Aneurysm, False , Aneurysm , Embolization, Therapeutic , Robotics , Humans , Female , Adult , Middle Aged , Renal Artery/diagnostic imaging , Hematuria/etiology , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Aneurysm, False/therapy , Nephrectomy/adverse effects , Embolization, Therapeutic/adverse effects , Nephrons , Aneurysm/complications , Aneurysm/surgery
4.
BMJ Case Rep ; 17(4)2024 Apr 19.
Article En | MEDLINE | ID: mdl-38642934

We present a fatal complication of treatment in a patient with early-onset acromegaly, treated with two transsphenoidal operations, radiotherapy, radiosurgery and pegvisomant. He was diagnosed in his 30s, and controlled from his 40s, with stable residual tumour within the left cavernous sinus. In his 60s, 30 years after surgery/radiotherapy and 14 years after radiosurgery, he developed recurrent episodes of mild epistaxis. A week later, he presented at his local hospital's emergency department with severe epistaxis and altered consciousness. He was diagnosed with a ruptured internal carotid artery (ICA) pseudoaneurysm, but unfortunately died before treatment could be attempted.ICA pseudoaneurysms are rare complications of surgery or radiotherapy and can present with several years of delay, often with epistaxis. This case highlights the importance of life-long monitoring in patients with previous pituitary interventions and early recognition of epistaxis as a herald sign of a potentially catastrophic event, thus leading to timely treatment.


Acromegaly , Aneurysm, False , Humans , Male , Acromegaly/complications , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Aneurysm, False/therapy , Carotid Artery, Internal , Epistaxis/etiology , Epistaxis/therapy , Epistaxis/diagnosis , Pituitary Gland , Aged
5.
Am J Case Rep ; 25: e942746, 2024 Apr 03.
Article En | MEDLINE | ID: mdl-38566390

BACKGROUND RARP is an established procedure in treatment of localized prostate cancer. Hemorrhagic complications in the postoperative period are rare, but sometimes life-threatening. Adequate monitoring and prompt intervention in these unusual scenarios rely on clinical judgement and blood and imaging studies. Prostatic fossa pseudoaneurysm formation after RARP is very rare and its etiology is not well known; it may be related to small vessel trauma. It becomes apparent with the development of hematuria 1-6 weeks after surgery. CASE REPORT A 58-year-old man underwent RARP with extended lymph node dissection for intermediate-risk prostate cancer, with bilateral preservation of neurovascular bundles and puboprostatic ligaments. He was discharged on day 2 without complications. In the following 4 weeks he came to the Emergency Department 3 times with hematuria and acute urinary retention. Four weeks after surgery, a pelvic CT angiogram showed a 20-mm pseudoaneurysm in the prostatic fossa, which was embolized by percutaneous angiography, with resolution of symptoms. He was discharged soon thereafter. CONCLUSIONS This case study describes a patient with prostatic fossa pseudoaneurysm after RARP. It was diagnosed 1 month after surgery and effectively managed by percutaneous embolization. Despite being a very rare condition, it must be kept in mind, especially when postoperative hematuria develops 1-6 weeks after surgery. Use of a management algorithm including serial blood tests, CT angiogram, and percutaneous angiography can lead to early detection and avoid life-threatening hemorrhage and overall postoperative morbidity.


Aneurysm, False , Prostatic Neoplasms , Robotics , Male , Humans , Middle Aged , Hematuria/etiology , Hematuria/surgery , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Aneurysm, False/therapy , Prostatectomy/adverse effects , Prostatectomy/methods , Prostatic Neoplasms/surgery , Prostatic Neoplasms/pathology , Treatment Outcome
6.
Medicine (Baltimore) ; 103(17): e37978, 2024 Apr 26.
Article En | MEDLINE | ID: mdl-38669393

RATIONALE: Visceral artery aneurysm is a rare and potentially fatal vascular condition that typically affects the superior mesenteric or inferior mesenteric arteries, the splenic, hepatic, and celiac arteries, as well as their branches. Visceral artery aneurysms can usually be treated using endovascular intervention, open surgery, or percutaneous thrombin injection. PATIENT CONCERNS: A 9-year-old girl was admitted to our trauma center with abdominal and bilateral leg pain after a car accident involving a head-on collision. DIAGNOSIS: Abdominal computed tomography (CT) showed bowel herniation through a muscle defect in the left lateral abdominal wall. There was a small amount of fluid around the liver and spleen, mild thickening of the small bowel wall, and infiltration in the small bowel mesentery, indicating the possibility of small bowel injury. INTERVENTIONS: Emergent exploratory laparotomy was performed. After resection of the ischemic parts of the terminal ileum and sigmoid colon, intestinal continuity was reestablished. Primary repair was performed on a traumatic left lateral abdominal wall hernia. She recovered well postoperatively without any complications. A follow-up abdominal CT scan after 2 months showed a pseudoaneurysm of the ileal branch of the superior mesenteric artery. Despite the absence of any gastrointestinal symptoms, the pseudoaneurysm was treated by endovascular intervention using numerous coils because of the significant risk of delayed rupture or massive bleeding. OUTCOMES: Follow-up abdominal CT scan after 6 months showed complete occlusion and resorption of the pseudoaneurysm. LESSONS: Although it is technically challenging, endovascular coil embolization may be a feasible technique in children with traumatic visceral artery pseudoaneurysms without complications.


Aneurysm, False , Endovascular Procedures , Mesenteric Artery, Superior , Humans , Female , Child , Aneurysm, False/etiology , Aneurysm, False/therapy , Aneurysm, False/surgery , Mesenteric Artery, Superior/injuries , Mesenteric Artery, Superior/diagnostic imaging , Mesenteric Artery, Superior/surgery , Endovascular Procedures/methods , Ileum/blood supply , Accidents, Traffic , Tomography, X-Ray Computed , Abdominal Injuries/complications , Embolization, Therapeutic/methods
7.
World J Surg ; 48(3): 560-567, 2024 Mar.
Article En | MEDLINE | ID: mdl-38501570

BACKGROUND: Nonoperative management of abdominal trauma can be complicated by the development of delayed pseudoaneurysms. Early intervention reduces the risk of rupture and decreases mortality. The objective of this study is to determine the utility of repeat computed tomography (CT) imaging in detecting delayed pseudoaneurysms in patients with abdominal solid organ injury. METHODS: A retrospective cohort study reviewing Montreal General Hospital registry between 2013 and 2019. Patients with The American Association for the Surgery of Trauma (AAST) grade 3 or higher solid organ injury following abdominal trauma were identified. A chart review was completed, and demographics, mechanism of injury, Injury Severity Score (ISS) score, AAST injury grade, CT imaging reports, and interventions were collected. Descriptive analysis and logistic regression model were completed. RESULTS: We identified 195 patients with 214 solid organ injuries. The average age was 38.6 years; 28.2% were female, 90.3% had blunt trauma, and 9.7% had penetrating trauma. The average ISS score was 25.4 (SD 12.8) in patients without pseudoaneurysms and 19.5 (SD 8.6) in those who subsequently developed pseudoaneurysms. The initial management was nonoperative in 57.0% of the patients; 30.4% had initial angioembolization, and 12.6% went to the operating room. Of the cohort, 11.7% had pseudoaneurysms detected on repeat CT imaging within 72 h. Grade 3 represents the majority of the injuries at 68.0%. The majority of these patients underwent angioembolization. CONCLUSIONS: In patients with high-grade solid organ injury following abdominal trauma, repeat CT imaging within 72 h enabled the detection of delayed development of pseudoaneurysms in 11.7% of injuries. The majority of the patients were asymptomatic.


Abdominal Injuries , Aneurysm, False , Wounds, Nonpenetrating , Humans , Female , Adult , Male , Retrospective Studies , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Aneurysm, False/therapy , Spleen/injuries , Abdominal Injuries/complications , Abdominal Injuries/diagnostic imaging , Abdominal Injuries/therapy , Wounds, Nonpenetrating/complications , Wounds, Nonpenetrating/diagnostic imaging , Wounds, Nonpenetrating/therapy , Injury Severity Score
11.
Medicine (Baltimore) ; 103(10): e37402, 2024 Mar 08.
Article En | MEDLINE | ID: mdl-38457581

RATIONALE: This case report discusses the CT-guided percutaneous drainage of a pancreatic pseudocyst accompanied by a pseudoaneurysm. Pancreatic pseudocysts can erode the peripancreatic artery and produce pseudoaneurysms. This is rare, but it can be life-threatening. PATIENT CONCERNS: The case presented involves a 58-year-old female who was diagnosed with pancreatic cancer and underwent surgical treatment. She presented with hematochezia, dizziness, and hypodynamic findings with no obvious cause. Imaging revealed a pancreatic pseudocyst and small arterial aneurysms. To reduce the risk of aneurysm rupture, the patient underwent transcatheter arterial coil embolization. Three days later, CT-guided catheter drainage was performed to reduce the erosion of the arterial wall caused by pancreatic fluid. DIAGNOSES: The contrast-enhanced-CT imaging showed a round, slightly high-density lesion in the cyst, suggesting the presence of a pseudoaneurysm. INTERVENTIONS: The patient was sent for another transcatheter arterial embolization with coils and n-butyl-2-cyanoacrylate. OUTCOMES: After receiving the transcatheter arterial embolization, the patient had no serious bleeding or other complications. LESSONS: Early detection and accurate assessment of pseudoaneurysms are essential for appropriate management. This case shows that contrast-enhanced CT is necessary before CT-guided percutaneous drainage of pancreatic pseudocysts. It also shows that, due to the many complications that pancreatic pseudocysts may cause, appropriate treatment of pseudocysts complicated with pseudoaneurysm has important clinical significance.


Aneurysm, False , Aneurysm, Ruptured , Pancreatic Pseudocyst , Female , Humans , Middle Aged , Pancreatic Pseudocyst/complications , Pancreatic Pseudocyst/diagnostic imaging , Pancreatic Pseudocyst/surgery , Aneurysm, False/complications , Aneurysm, False/diagnostic imaging , Aneurysm, False/therapy , Tomography, X-Ray Computed/adverse effects , Aneurysm, Ruptured/complications , Drainage/methods
12.
Clin J Gastroenterol ; 17(2): 352-355, 2024 Apr.
Article En | MEDLINE | ID: mdl-38363445

Hepatic artery pseudoaneurysms have been reported to occur in approximately 1% of cases after metal stenting for malignant biliary obstruction. In contrast, only a few cases have been reported as complications after plastic stenting for benign biliary disease. We report a 61-year-old man with cholangitis who presented with a rare complication of hemobilia after implantation of 7 Fr double pigtail plastic biliary stents. No bleeding was observed approximately one month after biliary stent tube removal. Contrast-enhanced CT scan revealed a circularly enhanced lesion (5 mm in diameter) in the arterial phase at the tip of the previously inserted plastic bile duct stent. Color Doppler ultrasonography enhanced the lesion and detected arterial blood flow inside. He was diagnosed with a hepatic artery pseudoaneurysm. However, he had no risk factors such as prolonged catheterization, severe cholangitis, liver abscess, or long-term steroid use. Superselective transarterial embolization using two metal microcoils was successfully completed without damage to the surrounding liver parenchyma. If hemobilia is suspected after insertion of a plastic bile duct stent, immediate monitoring using contrast-enhanced computed tomography or Doppler ultrasonography is recommended.


Aneurysm, False , Cholangitis , Hemobilia , Male , Humans , Middle Aged , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Aneurysm, False/therapy , Hemobilia/therapy , Hemobilia/complications , Hepatic Artery/diagnostic imaging , Hepatic Artery/pathology , Incidence , Cholangitis/complications , Stents/adverse effects
13.
BMJ Case Rep ; 17(2)2024 Feb 27.
Article En | MEDLINE | ID: mdl-38417939

Skull base osteomyelitis can be more life-threatening in immunocompromised patients and patients with diabetes. Here, we present a case of a petrous internal carotid artery pseudoaneurysm resulting from skull base osteomyelitis in a diabetic male in his 50s. This case report highlights the need to be conscious of the various complications associated with skull base osteomyelitis, be proficient in detecting them and treat them as early as possible for better outcomes. After adequate control of the disease process with medical treatment, immediate management of the aneurysm with balloon angioplasty and stenting was done. Acknowledging the trivial nasal and ear bleed, radiological evaluation is necessary to rule out rare complications like pseudoaneurysms in a diagnosed case of skull base osteomyelitis. In the discussion, we have cited the various treatment methods and similar cases of pseudoaneurysm caused by osteomyelitis. Currently, the patient continues to live a disease and disability-free life.


Aneurysm, False , Aneurysm , Osteomyelitis , Humans , Male , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Aneurysm, False/therapy , Skull Base/diagnostic imaging , Skull Base/surgery , Aneurysm/complications , Radiography , Carotid Artery, Internal/surgery , Osteomyelitis/diagnostic imaging , Osteomyelitis/therapy , Osteomyelitis/complications
14.
World Neurosurg ; 184: e603-e612, 2024 Apr.
Article En | MEDLINE | ID: mdl-38336211

BACKGROUND: The optimal stenting approach for traumatic pseudoaneurysms (PSA) of the extracranial internal carotid artery (ICA) remains underinvestigated. We present a case of a traumatic pseudoaneurysm of the extracranial ICA managed with stenting and review of prior published similar cases. METHODS: The systematic review followed PRISMA-S guidelines and included studies that investigated traumatic pseudoaneurysms of the extracranial ICA managed by stent placement. Statistical analysis assessed the association between the type of injury and stent type, dual antiplatelet therapy (DAPT) duration, and clinical presentation, and the association between stent type and DAPT duration. RESULTS: Our search yielded 82 publications with 135 patients with extracranial ICA PSA treated with stenting. The odds of neck hematoma presentation was 12.2 times greater for patients with penetrating rather than blunt injuries (P = 0.000002). Covered stents had 2.02 times higher odds of use for penetrating rather than blunt injuries compared to bare metal stents. (P = 0.0029). Shorter duration DAPT was seen with bare metal stents having 1.25 higher odds of DAPT duration less than one month compared to covered (P = 0.001). CONCLUSIONS: In traumatic extracranial ICA pseudoaneurysms, covered stents are used more commonly for penetrating injuries compared to blunt injuries. Penetrating injuries are more strongly associated with the presentation of a hematoma compared to blunt injuries. Stent type may influence the recommended DAPT duration. Surgeons should consider these findings when selecting stent type and DAPT duration with patients presenting with traumatic extracranial ICA pseudoaneurysm.


Aneurysm, False , Carotid Artery Injuries , Endovascular Procedures , Wounds, Nonpenetrating , Humans , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Aneurysm, False/therapy , Carotid Artery, Internal/diagnostic imaging , Carotid Artery, Internal/surgery , Carotid Artery Injuries/diagnostic imaging , Carotid Artery Injuries/etiology , Carotid Artery Injuries/surgery , Platelet Aggregation Inhibitors/therapeutic use , Stents/adverse effects , Wounds, Nonpenetrating/complications , Wounds, Nonpenetrating/surgery , Hematoma/complications , Treatment Outcome , Endovascular Procedures/adverse effects
15.
J Invasive Cardiol ; 36(5)2024 May.
Article En | MEDLINE | ID: mdl-38422531

A 78-year-old male patient with a history of coronary artery disease (he had undergone coronary artery bypass surgery 4 years ago), heart failure with mildly reduced ejection fraction, diabetes mellitus, and transient ischemic attack presented to the emergency department with complaints of dyspnea (New York Heart Association Class 4) despite the optimal medical therapy.


Aneurysm, False , Cardiac Catheterization , Heart Ventricles , Humans , Male , Aged , Aneurysm, False/diagnosis , Aneurysm, False/surgery , Aneurysm, False/therapy , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Cardiac Catheterization/methods , Heart Aneurysm/diagnosis , Heart Aneurysm/surgery , Treatment Outcome , Coronary Artery Disease/diagnosis , Coronary Artery Disease/surgery , Coronary Artery Disease/therapy
16.
Vasc Endovascular Surg ; 58(5): 567-570, 2024 Jul.
Article En | MEDLINE | ID: mdl-38240584

Coil migration during endovascular embolization is a complication that can result in thromboembolic occlusion leading to potentially large infarcts if not removed. Microsnares are commonly used to remove migrated coils. Current techniques, however, struggle in cases where the microsnare is unable to loop over and secure a free end of the coil. We present a case in which a microsnare combined with a microwire successfully removed a migrated coil in a patient with a bleeding hepatic pseudoaneurysm post-embolization. This technique proved beneficial when traditional methods were insufficient, especially in small vessels or coil packs that cannot be snared. The synergy of the microsnare and microwire technique presents a promising solution for challenging migrated coil retrievals.


Aneurysm, False , Device Removal , Embolization, Therapeutic , Foreign-Body Migration , Humans , Foreign-Body Migration/etiology , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/therapy , Foreign-Body Migration/surgery , Embolization, Therapeutic/instrumentation , Treatment Outcome , Aneurysm, False/diagnostic imaging , Aneurysm, False/therapy , Aneurysm, False/etiology , Hepatic Artery/diagnostic imaging , Male , Hemorrhage/etiology , Hemorrhage/therapy , Aged , Equipment Design , Female
17.
Cardiovasc Revasc Med ; 62: 105-118, 2024 May.
Article En | MEDLINE | ID: mdl-38212236

BACKGROUND: Percutaneous closure of aortic and ventricular pseudoaneurysms (PSA) has only been reported on a case report and series basis. In previous case reports, percutaneous closure has been performed successfully in patients of prohibitive surgical risk. This case series aims to show feasibility of percutaneous closure of aortic and ventricular pseudoaneurysm secondary to perivalvular leak (PVL) in a small patient population and the utility of multimodality imaging as an integral tool in procedural planning. This is the largest complex case series to date describing the feasibility and success rate of complex PSA closure, with a follow-up period of up to 4 years. MATERIAL AND METHODS: We performed institutional review and systemic literature review to identify all paravalvular leak cases with associated pseudoaneurysm formation for which a closure procedure was performed. Ten patients were identified. Pooled analysis for cases from institutional review (n = 10) and systemic literature review (n = 39) was performed. The success rate was 100 %. At 30-days, the mortality was 0 %. CONCLUSION: In paravalvular leak patients with subsequent pseudoaneurysm formation, exhaustive imaging evaluation is required for closure. However, it can be achievable with favorable rates of success.


Aneurysm, False , Heart Valve Prosthesis Implantation , Humans , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Aneurysm, False/therapy , Male , Female , Treatment Outcome , Aged , Middle Aged , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Aneurysm/diagnostic imaging , Heart Aneurysm/etiology , Heart Aneurysm/therapy , Cardiac Catheterization/adverse effects , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/surgery , Time Factors , Aged, 80 and over , Heart Valve Prosthesis , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Echocardiography, Transesophageal , Adult
19.
Article En | MEDLINE | ID: mdl-38250571

Left ventricular assist devices (LVAD) are surgically implanted mechanical support devices utilized with increasing frequency as a bridge to myocardial recovery, destination therapy, and heart transplantation. While the use of such devices in patients with advanced heart failure has shown significant survival benefits and improved quality of life, they bear their own risks and complications.1 Bleeding, infection, pump thrombosis, and stroke are just some of the serious complications associated with LVADs.2 LVAD-associated pseudoaneurysms are rare, with prior reports of occurrence at the left ventricular apex and at the anastomosis site of the outflow graft to the ascending aorta.3,4 Typically, this device-related complication requires surgical repair and, if at all feasible, heart transplantation. However, in cases of difficult anatomy, unfavorable position, and significant comorbidities, surgery may be contraindicated due to high surgical risk. This case portrays a patient suffering from a left ventricular pseudoaneurysm after HeartMate-III implantation that was not amenable to surgical repair due to heightened surgical risk. We document the first pseudoaneurysm associated with the HeartMate-III in available literature and describe a novel management strategy of documented nonoperative course of LVAD-associated pseudoaneurysm, with the patient surviving 56+ months with medical optimization and management.


Aneurysm, False , Heart-Assist Devices , Humans , Conservative Treatment , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Aneurysm, False/therapy , Quality of Life , Aorta
20.
Clin Radiol ; 79(1): e189-e195, 2024 Jan.
Article En | MEDLINE | ID: mdl-37949801

AIM: To report the authors' experience of bronchial artery embolisation (BAE) in a series of patients to control haemoptysis associated with infected pulmonary artery pseudoaneurysms (PAPs). MATERIALS AND METHODS: All patients who underwent BAE based on computed tomography angiography (CTA) findings indicative of haemoptysis between February 2019 and September 2022 at Xiangyang Central Hospital were identified. Charts of patients with haemoptysis and infectious PAPs were reviewed retrospectively. Data were collected data on age, sex, underlying pathology, source pulmonary artery of the PAP, association with cavitary lesions or consolidation, systemic angiography findings, technical and clinical success, and follow-up. RESULTS: Seventeen PAPs were treated in 16 patients, with a mean age of 60.3 years (range: 37-82 years). The most common underlying cause was tuberculosis (15/16, 93.8%). Imaging by CTA did not identify the source pulmonary artery for 15 (88.2%) PAPs; all were associated with cavitary lesions or consolidation. All PAPs were visualised on systemic angiography. The technical and clinical success rates were both 87.5%. Two patients who experienced a recurrence of haemoptysis during follow-up underwent repeat CTA, which confirmed the elimination of the previous PAP. CONCLUSION: BAE may be a valuable technique to control haemoptysis associated with infectious PAPs that are visualised on systemic angiography. A possible contributing factor is PAPs arising from very small pulmonary arteries.


Aneurysm, False , Embolization, Therapeutic , Humans , Middle Aged , Pulmonary Artery/diagnostic imaging , Aneurysm, False/complications , Aneurysm, False/diagnostic imaging , Aneurysm, False/therapy , Retrospective Studies , Hemoptysis/diagnostic imaging , Hemoptysis/etiology , Hemoptysis/therapy , Angiography/methods , Bronchial Arteries/diagnostic imaging , Embolization, Therapeutic/methods , Treatment Outcome
...